P2670: Voedingsspanning B van de actuatoren — circuit laag
Wat te doen
Expect several warning lights and reduced power, probably coming and going rather than being constant.
As at P2669, do not let a list of unrelated parts be replaced on the strength of these codes. A shared power supply has failed and everything on it reports itself faulty.
Mention exactly when it happens — under load, going up a hill, with the air conditioning on, in a particular gear. A supply that fails only when several parts draw current at once points at a weak connection rather than a dead short, and that is a different and much cheaper repair. Ask for voltage-drop testing while the circuit is working, not just a continuity check, because a bad joint measures perfectly when nothing is flowing through it.
If the supply itself tests sound, the remaining possibility is one faulty part dragging the shared supply down — and that is found by disconnecting them one at a time, not by replacing them all.
Wat deze code betekent
The second actuator supply rail reads below its valid range — a short to ground, or a supply that has collapsed under load.
What a supply rail is, and why its failure produces a list of codes naming unrelated healthy parts, is explained at P2669.
The distinction that matters on this code is between a rail that is shorted and a rail that is merely sagging, because they lead to different repairs. A dead short pulls the rail down whenever it is switched on, and the module usually shuts it off protectively — everything on the rail stops together and stays stopped. A rail sagging under load behaves quite differently: it holds up at idle with few actuators working and drops when several draw current at once, so the faults appear under load, in a particular gear, or only with the air conditioning on. That intermittency reads as several flaky components rather than one weak supply.
A sagging rail is nearly always resistance in the supply path rather than a short at all — a relay whose contacts have degraded, a corroded ground, a connector pin that has lost tension. The test is voltage drop while the rail is loaded, not a static reading, because a resistive joint measures perfectly at rest.
One actuator can also pull the rail down on its own: a solenoid whose winding has shorted internally draws far more than its share and starves everything beside it. That is the one case where a component named by another code genuinely is the culprit — so if the supply path measures sound under load, the next step is disconnecting the rail's actuators one at a time.
Waarschijnlijke oorzaken
Begin hier
- Bedrading kortgesloten met massa · gemiddeld
- Hoge weerstand in de voeding van de module · gemiddeld
- Slechte massaverbinding van de module · gemiddeld
- Voedingsrelais van de module defect · gemiddeld
Minder vaak
- Kortgesloten injector trekt de eindtrap omlaag · gemiddeld
- Voedingsbedrading van de module beschadigd · gemiddeld
Symptomen
Betrokken onderdelen
Informatie, geen instructie
CarGeek is een naslagwerk, geen werkplaatshandboek. De pagina's zijn geschreven op basis van openbare bronnen en van wat anderen hebben ondervonden, nooit op basis van de servicedocumentatie van de fabrikant zelf, dus ze kunnen onjuist of onvolledig zijn voor jouw specifieke voertuig. Een deel van wat erin staat brengt echt gevaar met zich mee: hoogspanning, brandstof onder druk, opgeslagen energie en hete of bewegende delen.
Laat alles waarnaar je wilt handelen eerst controleren door iemand met een technische opleiding, aan de hand van de eigen procedure van de fabrikant voor jouw voertuig. Niets hier vervangt die procedure.
Ervaring uit de community
Wees de eerste die dit beschrijft
Hierover is nog niets geplaatst. Wat je ook hebt gevonden, het is het opschrijven waard — zelfs een doodlopend spoor bespaart iemand dezelfde middag.
Wat het de moeite waard maakt:
- De auto — merk, model, bouwjaar en motor. Dezelfde storing gedraagt zich per auto anders.
- Wat je gemeten hebt, niet alleen wat je vervangen hebt.
- Wat het echt verholpen heeft — of dat niets dat deed, wat ook nuttig is om te weten.
Inloggen of een account aanmaken om toe te voegen wat je hebt gevonden over P2670.