Decides whether coolant flows through the radiator or bypasses it — the job a wax thermostat used to do, moved under the module's control.
That change matters more than it sounds. A thermostat opens at one temperature fixed when it was made, which is a compromise: an engine is most efficient hot, but a hot engine has less margin against detonation and less capacity to absorb heat under load. An electrically controlled valve lets the module pick a target by conditions — deliberately hot at light load, deliberately cooler when working hard. Coolant temperature stops being a property of the engine and becomes a control variable.
The diagnostic consequence is that an old rule of thumb has stopped being reliable. "It never warms up, so it needs a thermostat" was sound for decades; on an engine with this valve, slow warm-up is at least as likely to be the valve or its circuit. Fitting a thermostat to an engine whose temperature is controlled by something else is a real and common wasted repair.
Most failures default toward cooling, which is the safe direction — expect an engine that runs cool and warms slowly. The exception is a valve held in bypass, where coolant circulates without reaching the radiator and temperature climbs steadily; a rising gauge alongside a cabin heater blowing hotter than usual is that case, and it is one to stop for.
También conocido como: coolant bypass valve, electric thermostat, map controlled thermostat, thermal management valve, coolant control valve, rotary coolant valve
Referenciado por 42 códigos
Códigos que involucran este componente (42)
- P26AB Válvula de derivación A del refrigerante del motor — bloqueado abierto Alta
- P2681 Válvula de derivación A del refrigerante del motor — circuito de control abierto Moderada
- P2682 Válvula de derivación A del refrigerante del motor — circuito de control bajo Moderada
- P2683 Válvula de derivación A del refrigerante del motor — circuito de control alto Moderada
- P26A3 Válvula de derivación A del refrigerante del motor — rango/rendimiento Moderada
- P26A6 Sensor de posición de la válvula de derivación A del refrigerante del motor — circuito bajo Moderada
- P2AA7 Sensor de posición de la válvula de derivación B del refrigerante del motor — circuito Moderada
- P2AA8 Sensor de posición de la válvula de derivación B del refrigerante del motor — circuito, rango/rendimiento Moderada
- P2AA9 Sensor de posición de la válvula de derivación B del refrigerante del motor — circuito bajo Moderada
- P2AAA Sensor de posición de la válvula de derivación B del refrigerante del motor — circuito alto Moderada
- P2AAB Sensor de posición de la válvula de derivación B del refrigerante del motor — circuito intermitente/errático Moderada
- U0615 Pérdida de comunicación con la válvula A de derivación del refrigerante del motor Moderada
- P26A4 Sensor de posición de la válvula de derivación A del refrigerante del motor — circuito
- P26A5 Sensor de posición de la válvula de derivación A del refrigerante del motor — circuito, rango/rendimiento
- P26A7 Sensor de posición de la válvula de derivación A del refrigerante del motor — circuito alto
- P26A8 Sensor de posición de la válvula de derivación A del refrigerante del motor — circuito intermitente/errático
- P26A9 Sensor de posición de la válvula de derivación A del refrigerante del motor — rendimiento del tope o del tope mínimo
- P26AA Sensor de posición de la válvula de derivación A del refrigerante del motor — rendimiento del tope máximo
- P26AC Válvula de derivación B del refrigerante del motor — circuito de control abierto
- P26AD Válvula de derivación B del refrigerante del motor — circuito de control bajo
- P26AE Válvula de derivación B del refrigerante del motor — circuito de control alto
- P26AF Válvula de derivación B del refrigerante del motor — bloqueado abierto
- P26B0 Válvula de derivación B del refrigerante del motor — rango/rendimiento
- P26B1 Válvula de derivación A del refrigerante del motor — bloqueado cerrado
- P26B2 Válvula de derivación B del refrigerante del motor — bloqueado cerrado
Otros componentes en Cooling
- Bomba eléctrica de refrigerante 149
- Sensor de temperatura del refrigerante 105
- Válvula de control del caudal de refrigerante 82
- Radiador 61
- Módulo de la persiana activa de la parrilla 53
- Termostato 40
- Ventilador de refrigeración 40
- Sensor de nivel del refrigerante 15
- Bomba de agua 12
- Sensor de temperatura del refrigerante del radiador 11
- Depósito de expansión del refrigerante 8
- Calefactor alimentado por combustible 5
- Válvula de purga del refrigerante 3
- Enfriador de aceite 1
Información, no instrucciones
CarGeek es una obra de referencia, no un manual de taller. Sus páginas se escriben a partir de fuentes públicas y de lo que otras personas han comprobado, nunca a partir de la documentación de servicio del fabricante, de modo que pueden ser incorrectas o incompletas para su vehículo concreto. Parte de lo que describen entraña un riesgo real: alta tensión, combustible a presión, energía acumulada y piezas calientes o en movimiento.
Antes de actuar sobre cualquier indicación, hágala verificar por una persona con formación técnica siguiendo el procedimiento propio del fabricante para su vehículo. Nada de lo que hay aquí sustituye ese procedimiento.
Trabajando en este componente
Sé el primero en documentarlo
Todavía no se ha publicado nada sobre esto. Todo lo que haya encontrado vale la pena anotarlo — incluso un callejón sin salida le ahorra a alguien esa misma tarde.
Lo que hace que valga la pena leerlo:
- El coche — marca, modelo, año y motor. La misma avería se comporta distinto en cada uno.
- Lo que mediste, no solo lo que cambiaste.
- Qué lo solucionó de verdad — o que nada lo hizo, que también conviene saber.
Iniciar sesión o crear una cuenta para agregar lo que encontró sobre Válvula de derivación del refrigerante del motor.