P2444: Pompe du système d'air secondaire — bloqué activé, banc 1

WhatsApp Telegram X E-mail

Que faire

Worth attending to quickly rather than at the next service. Expect poor economy, a rough idle and possibly an audible pump running when it should be silent. Two things are being damaged meanwhile: the pump itself, which is built for about a minute of running per cold start and will burn out if held on, and the catalytic converter, because the extra air makes the sensors read lean and the engine is over-fuelled in response. Ask for the pump relay to be tested first — a relay with welded contacts holds the pump on regardless of what the module wants, and it is much the cheapest of the possible causes.

Ce que signifie ce code

The bank 1 secondary air pump is running when it should not be.

This does everything the stuck-open valve at P2440 does, and adds two problems of its own.

The shared consequence first: air pumped into the exhaust outside the cold-start window makes the oxygen sensors report a lean mixture that is not there, so the module over-fuels and the engine runs genuinely rich. The full argument is at P2440 and applies unchanged.

What is specific to the pump running is that the pump is not built for it. These are simple electric air pumps rated for a short burst — thirty to ninety seconds once per cold start, which over a day amounts to a couple of minutes of running. Asked to run continuously, one will overheat and destroy itself, usually within hours rather than weeks. So this code has a deadline of its own: the longer it stays unrepaired, the more likely the fault becomes a pump replacement as well.

And it draws current the whole time. On a vehicle left parked with the pump running, that is a flat battery; on a vehicle in use, it is a constant load the charging system was not asked to carry.

The cause is very often the relay rather than the pump or the module. A relay switching a heavy current in short bursts is exactly the duty that pits and eventually welds contacts, and a welded relay holds the pump on regardless of what the module commands. That is a cheap part, and it is worth testing before anything larger is considered — including before the module is suspected of commanding the pump wrongly.

Causes probables

Commencez ici

Moins fréquent

Rare

Symptômes

Composants concernés

Des informations, pas des instructions

CarGeek est un ouvrage de référence, pas un manuel d'atelier. Ses pages sont rédigées à partir de sources publiques et de ce que d'autres ont constaté, jamais à partir de la documentation technique du constructeur ; elles peuvent donc être erronées ou incomplètes pour votre véhicule précis. Une partie de ce qu'elles décrivent présente un risque réel : haute tension, carburant sous pression, énergie accumulée, pièces chaudes ou en mouvement.

Avant d'agir sur quoi que ce soit, faites-le vérifier par une personne formée, en suivant la procédure du constructeur pour votre véhicule. Rien ici ne remplace cette procédure.

Expérience de la communauté

Soyez le premier à en faire le compte rendu

Rien n'a encore été publié à ce sujet. Tout ce que vous avez trouvé mérite d'être noté — même une impasse épargne à quelqu'un le même après-midi.

Ce qui rend un compte rendu utile :

  • La voiture — marque, modèle, année et moteur. La même panne ne se comporte pas pareil sur chacune.
  • Ce que vous avez mesuré, pas seulement ce que vous avez remplacé.
  • Ce qui a réellement résolu le problème — ou que rien ne l’a résolu, ce qui est utile aussi.

Se connecter ou créer un compte pour ajouter ce que vous avez trouvé à propos de P2444.